Digital temperature control device with double contact and designed with micro-controllers capable of controlling över adjustable time rate.
GENERAL SPECIFICATIONS
*Digital temperature control device with double contact and
designed with micro-controllers capable of controlling över
adjustable time rate
*96mm x 96mm cross-section for panel mount
*Set point temperature with the actual temperature are displayed
simultaneously.
*Easy and clear programming wirh the aid of buttons on the
front panel*Double set point
*Easiness of connection with socketted xlemens
TECHNICAL SPECIFICATIC
Dimensions W96xH96xD107
Display 3 Digit 20mm 7 Segmented Red Led
3 Digit 14 mm, 7 Segmented Green Led
Scale 0 - 500 °C
Input Fe- Const. (PT-100 must be mentioned
with order)
Resolution 1°C
Accuracy ±%0.5 (Över Full Scale)
Control Type ON-OFF and time rate if ali the
parameters are kept at minimum
Control Outputl Time rate according to Seti
Control Outpub2 ON - OFF according to Set2
Rate Band (HYH) 0 - 20°C
Rate of Time (dt) 2-20s
Supply Voltage 220 VAC +%15,-%20,50-60 Hz, Uax. 3 VA
PowerConsumption 3VA
Amnbience Temperature
Compensation 0 - 50-C
AmbienceTemp. Range 0.. +50DC
Buttons Micro-svvitch
Vveight 425 gr
DIMESIONS
PROGRAMMING
Programming options for TE 9696 D are simple, targeting ones needs with clear programming algorithm.
The value of Seti can be adjusted just with buttons
and
Value can be increased or decreased one by one pressing the buttons at a time. If one of the buttons are pressed continuously for 3 seconds adjustment can be done more faster. After adjustment is done the new value for Seti is stored in the memory.
Programming options for TE 9696 D are simple, targeting ones needs with clear programming algorithm.
The value of Seti can be adjusted just with buttons
After PRG button is pressed for 5 seconds ST2 value will be di- splayed.
and
buttons are used to adjust St2.
Second time the PRG button is pressed rl2 option is displayed and Set2 can be activated (ON) or de-activated (OFF) with
and
buttons.
Third time the PRG button is pressed rl2 option with two choices: h ı or Lo are displayed and can be selected with and When Lo is selected relay2 is activated when the temperature is belovv the value of set2. If h ı is selected then relay2 will be activated when the temperature is equal or higher then that of set2.
Fourth time the PRG button is pressed HYH option is displayed. With
and
buttons the rate band value can be selected be- tween1 ° Cto20 ° C
Fifth time the PRG button is pressed dt option is displayed. With
and
buttons the rate time value can be selected betvveen 2 seconds to 20 seconds.
If none of the buttons are pressed for a vvhile the thermostat will auto- matically store the changes and set back to normal operating mode
Time Rate Operating Mode
Rate band value (HYH) sets the temperature difference for which the time rate operating will be activated before the value of Setl.Time rate value (dt) sets the period time in seconds for relayl in time rate operating mode.
Example: HYH= 10 ° C, dt= 6 sec. And Setl=200 ° C At temperature Sefl - HYH = 200 ° C - 10 ° C = 190 ° C time rate opera ting mode starts and stops at Seti + 2 = 202 8C. The ON and OFF time for the relay is half of the period at 196 ° C (thats 3 sec. ON and 3 sec. OFF).